X2.2: Enabling Button Vac 30.2; Pin Assignment X2.2; Wiring The Enabling Button; X3: Ethernet Interface Vac 30.2 - Bosch Rexroth IndraControl VAM 11.1 Project Planning Manual

Table of Contents

Advertisement

DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels
7.8.5

X2.2: Enabling Button VAC 30.2

Pin Assignment X2.2

Wiring the Enabling Button

7.8.6

X3: Ethernet Interface VAC 30.2

DANGER
The circuit of the STOP button or EMERGENCY STOP button might be oper‐
ated with a maximum of 30 V and must be protected with a 2-A-fusible cut-out.
Pin
X2.2 pin1
X2.2 pin2
X2.2 pin3
X2.2 pin4
Fig.7-26:
Enabling button X2.2
DANGER
The circuit of the enabling device might be operated with a maximum of 30 V
and has to be protected with a 2-A-fusible cut-out.
The following special requirements apply for the connection between the hand-
held terminal (IndraControl VEH 30.1/30.2 or VCH 08.1) and the safety-related
evaluation for the enabling button: It is required that short-circuits and/or cross-
circuits on the safety-related signal paths are safely detected by evaluation
devices.
The simultaneity monitoring is to be carried out by the monitoring device. Oth‐
erwise, an unidentified error accumulation can occur and can diminish safety.
The EN 60204-1:1997 also specifies that the enabling device is to be connected
to a stop of the category 0 or 1, i.e. the energy must be switched off.
For further information on the wiring of the enabling button and
connection examples how category 3 can be reached by using the
hand-held terminals VCH 08.1 or VEH 30.1/30.2 and its safety-re‐
lated parts, please refer to the documentation of the hand-held
terminals IndraControl VEH 30.1 (DOK-SUPPL*-VEH*30.1***-
PR02-EN-P), IndraControl VEH 30.2 (DOK-SUPPL*-VEH*30.2***-
PR01-EN-P)
VCH*08.1***-PR01-EN-P).
The operator terminal can be connected to an Ethernet network via an Ethernet
interface.
RJ45, female connector, 8-pin
Type:
Cable length:
Bosch Rexroth AG
Risk of injury due to malfunction of the STOP
button or EMERGENCY STOP button.
Signal name
Enabling button 1 IN
Enabling button 1 OUT
Enabling button 2 IN
Enabling button 2 OUT
Risk of injury due to malfunction of the enabling
button.
or
IndraControl
VCH
Ethernet 10Base T / 100Base X
Max. 65 m; patch cable (category 6)
61/83
Interfaces
08.1
(DOK-SUPPL*-