Cutting Units Will Not Lower - Toro Reelmaster 5100-D Service Manual

Hide thumbs Also See for Reelmaster 5100-D:
Table of Contents

Advertisement

Cutting Units Will Not Lower

Cause
__
________________________________________________________________________________________
S3, S4, or S5 not shifting (See Hydraulic Schemat­
ics to see which valve controls what lift cylinders.)
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
S6 not shifting.
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
S7 shifted (should only be shifted during lift
function).
Troubleshooting
__
__
__
__
__
__
Page 4 - 24
Correction
Do electrical diagnostics to make sure that voltage
is being applied to solenoid for affected circuit and
that there is no electrical fault. See Chapter 5 - Elec ­
trical System.
Do cartridge valve service procedure for valve in af ­
fected circuit.
Interchange solenoid from affected circuit with an ­
other similar valve (S3, S4, or S5) and check opera­
tion. Replace affected valve with a new valve if faulty.
__
__
Do electrical diagnostics to make sure that voltage
is being applied to S6 and that there is no electrical
fault. See Chapter 5 - Electrical System.
Do cartridge valve service procedure for valve S6.
Replace S6 with a new valve if faulty.
__
__
Do electrical diagnostics to make sure that voltage
is being applied to S7 and that there is no electrical
fault. See Chapter 5 - Electrical System.
Do cartridge valve service procedure for valve S7.
__
__
®
Reelmaster
5100-D