Cutting Units Will Not Lower
Cause
__
________________________________________________________________________________________
S3, S4, or S5 not shifting (See Hydraulic Schemat
ics to see which valve controls what lift cylinders.)
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
S6 not shifting.
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
S7 shifted (should only be shifted during lift
function).
Troubleshooting
__
__
__
__
__
__
Page 4 - 24
Correction
Do electrical diagnostics to make sure that voltage
is being applied to solenoid for affected circuit and
that there is no electrical fault. See Chapter 5 - Elec
trical System.
Do cartridge valve service procedure for valve in af
fected circuit.
Interchange solenoid from affected circuit with an
other similar valve (S3, S4, or S5) and check opera
tion. Replace affected valve with a new valve if faulty.
__
__
Do electrical diagnostics to make sure that voltage
is being applied to S6 and that there is no electrical
fault. See Chapter 5 - Electrical System.
Do cartridge valve service procedure for valve S6.
Replace S6 with a new valve if faulty.
__
__
Do electrical diagnostics to make sure that voltage
is being applied to S7 and that there is no electrical
fault. See Chapter 5 - Electrical System.
Do cartridge valve service procedure for valve S7.
__
__
®
Reelmaster