General Run and Transport Problems
Condition
_________________________________________________________________________________________
Engine continues to run, but
should not, when ignition key is
turned off.
_____________ ________________ ______ ________________ ______ ________________ __________________________________
__
__
Engine continues to run, but
should not, when traction pedal is
engaged with no operator on seat.
_____________ ________________ ______ ________________ ______ ________________ __________________________________
__
__
Engine kills during operation, but
restarts.
®
Reelmaster
5100-D
Possible Cause
Engine fuel lever or run solenoid
stuck in "on" position.
Ignition switch faulty.
__
__
__
Seat switch circuit is closed.
Traction neutral switch circuit
closed.
__
__
__
Seat lifting off seat switch.
Seat switch circuit open.
Faulty ignition switch.
Faulty ignition switch wiring.
Page 5 - 11
Correction
Check operation of run solenoid
and adjust or replace if necessary.
Make sure fuel stop lever moves
without sticking and repair if
necessary.
Replace ignition switch.
__
Check seat plate hinges and seat
support pin and repair if faulty.
Check for water soaked seat
cushion.
Test seat switch and replace if
faulty.
Check seat switch wiring and
repair if faulty.
Check traction neutral switch
adjustment and adjust if faulty.
Test traction neutral switch and
replace if faulty.
Check traction neutral switch
wiring and repair if faulty.
__
Instruct operator to sit back in
seat during operation. Operate
machine slower when operating
in rough terrain.
Check seat plate hinges and seat
support pin and repair if faulty.
Test seat switch and replace if
faulty.
Check seat switch wiring and
repair if faulty.
Replace switch.
Repair wiring.
__
___
______________________________
___
______________________________
Troubleshooting