Cartridge Valve Identification
NOTE: When troubleshooting hydraulic problems, keep
in mind that is possible for some cartridge valves to be
installed in the wrong ports, causing the system to
malfunction.
Solenoid valves in valve block must not be interchanged
between ports, with the following exceptions:
S1 and S2 are the same design and can be inter
changed (Fig. 79).
S3, S4 and S5 are the same design and can be
interchanged (Fig. 80).
S7, S8 and S9 are the same design and can be
interchanged (Fig. 82).
Note position
of holes in cage
Figure 79
Solenoid valves S1 and S2
2 way spool valve – normally open
Note position
of holes in cage
Figure 80
Solenoid valves S3, S4 and S5
2 way spool valve – normally closed
Mowing Circuit Repairs
2 way pilot operated poppet valve – normally closed
Solenoid valve S7, S8 and S9
4 way 2 position spool valve
Page 4 - 56
Note poppet
valve
Figure 81
Solenoid valve S6
Figure 82
Reelmaster
®
5100-D