11. Check for continuity between a slip ring and shaft
(core) (Fig. 55). Replace the field coil if there is
continuity.
12. Check for continuity between lead wires of the stator
coil (Fig. 56). Replace the stator coil if there is no
continuity.
13. Check for continuity between each lead wire and
stator core (Fig. 57). Replace the stator coil if there is
continuity.
®
Reelmaster
5100-D
Page 5 - 43
Figure 55
Figure 56
Figure 57
Repairs