Cutting Unit(s) Will Not Raise
Cause
__
________________________________________________________________________________________
One-way variable orifice closed - center and rear
cutting units only - see Hydraulic Schematics.
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
Engine RPM too low.
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
S7 not shifting.
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
S3, S4, or S5 not shifting (See Hydraulic Schemat-
ics to see which valve controls what lift cylinders.)
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
R1 bypassing.
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
Internal leakage in lift cylinder(s).
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
Lift arm pivots binding.
_____________________________________________ ________________ ______ ________________ ______ ________________ ___________________________________
P1 pump section inefficient.
Troubleshooting
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
Page 4 - 22
Correction
Open speed control valve.
__
__
Increase engine RPM to operating speed.
__
__
Do electrical diagnostics to make sure that voltage
is being applied to S7 and that there is no electrical
fault. See Chapter 5 - Electrical System.
Test solenoid coil. Replace if faulty. See Chapter 5 -
Electrical System.
Oil viscosity too high - run machine to warm up oil to
operating temperature.
Do cartridge valve service procedure for valve S7.
__
__
Do electrical diagnostics to make sure that voltage
is being applied to solenoid for affected circuit and
that there is no electrical fault. See Chapter 5 - Elec
trical System.
Test solenoid coil for valve of affected circuit. Re
place if faulty. See Chapter 5 - Electrical System.
Do cartridge valve service procedure for valve in af
fected circuit.
Interchange solenoid from affected circuit with an
other similar valve (S3, S4, or S5) and check opera
tion. Replace or repair affected valve if faulty.
__
__
Check relief pressure at port G1 of valve block and
adjust valve if necessary.
Do cartridge valve service procedure for valve R1.
Replace R1 with a new valve.
__
__
Check lift cylinder(s) and repair or replace if faulty.
__
__
Lubricate bushings. Inspect for damage. Repair or
replace damaged parts.
__
__
Repair or replace pump.
__
__
__
__
__
__
__
®
Reelmaster
5100-D