Hydraulic Valve Block Solenoids

1. Disconnect the wire connector.
2. Connect a 12 volt battery so the positive (+) battery
terminal is connected to colored solenoid lead. Connect
the negative (–) battery terminal to black lead. The valve
spool should retract completely as 12 V.D.C is applied
between leads.
3. If valve spool does not retract check for binding or
damage in valve.
4. If valve operates smoothly, but does not retract when
12 V.D.C is applied to solenoid leads, replace solenoid
coil.
5. If valve still does not retract after replacing solenoid
coil, replace the valve.
NOTE: To to a quick test without removing solenoid
valve, hold a screwdriver to top of affected valve. When
solenoid is energized, screw driver should be attracted
to valve stem, due to magnetism from energized sole­
noid. This test will not identify a sticking valve spool.
Resistance specifications:
20 Watt solenoid:7.2 Ohms
28 Watt solenoid: 5.1 Ohms
Testing
Page 5 - 28 Rev. B
1
Figure 27
1. Solenoid
Solenoid Wire Identification
Solenoid
Power Wire Color
1S
Pink/Blue
2S
Brown/White
3S
Orange/Blue
4S
Yellow/Black
5S
Yellow/White
6S
Orange/Red
7S
Yellow/Blue
8S
Black/Red
9S
Brown/White
VS1
Orange/Black
VS2
Orange/White
Figure 28
Reelmaster
®
5100-D