Condition
_________________________________________________________________________________________
All electrical is dead, including
gauges.
_____________ ________________ ______ ________________ ______ ________________ __________________________________
__
__
Starter solenoid clicks, but starter
will not crank. (If solenoid clicks,
problem is not in interlock system
or controller.)
®
Reelmaster
5100-D
Possible Cause
Low battery charge.
Thermal circuit breaker No. 1 open.
5A key switch fuse open.
Faulty key switch wiring.
Faulty key switch.
__
__
__
Low battery charge.
Loose or corroded battery cables.
Loose or corroded ground.
Faulty wiring at starter.
Loose starter mounting bolts.
Faulty starter.
Faulty starter solenoid.
Page 5 - 9
Correction
Charge battery. Replace battery if
it will not hold a charge.
Find cause for open circuit
breaker and correct. Circuit
breaker will reset automatically
after has cooled.
Check fuse and replace if fuse is
open. If fuses burn out often, find
and correct cause. NOTE: If
auxillary lights are added, this
fuse must be replaced with a
15A fuse.
Repair wiring.
Test key switch and replace if
necessary.
__
Charge battery. Replace battery if
it will not hold a charge.
Clean and tighten or repair as
necessary.
Repair wiring.
Clean mounting surface and
tighten bolts.
Repair or replace starter.
Replace starter solenoid.
__
___