Repairs

IMPORTANT: Before welding on the machine, dis ­
connect both battery cables from the battery, dis ­
connect both wire harness plugs from the electronic
control unit and disconnect the terminal connector
from the alternator to prevent damage to the electri ­
cal system.

Battery Service

IMPORTANT: To prevent damage to the electrical
components, do not operate the engine with the
battery cables disconnected.
Keep the terminals and entire battery case clean. To
clean the battery, wash the entire case with a solution
of baking soda and water. Rinse with clear water. Do not
get the soda solution into the battery because damage
to the battery will result. Coat the battery posts and cable
connectors with skin-over grease, or petroleum jelly to
prevent corrosion.
Check for loose battery hold-downs. A loose battery may
crack or cause the container to wear and leak acid.
Check the electrolyte solution to make sure the level is
above the plates (Fig. 37). If the level is low (but above
the plates inside the battery), add water so the level is
to the bottom of the cap tubes. If the level is below the
plates, add water only until the plates are covered and
then charge the battery. After charging, fill the battery to
the proper level.
CAUTION
Do not charge a frozen battery because it can
explode and cause injury. Let the battery warm
o
o
to 60 F (15.5 C) before connecting to
charger.
Charge the battery in a well-ventilated place
so that gases produced while charging can
dissipate. Since the gases are explosive, keep
open flame and electrical spark away from the
battery; do not smoke. Nausea may result if
the gases are inhaled. Unplug the charger
from the electrical outlet before connecting or
disconnecting the charger leads from the bat ­
tery posts.

Repairs

Electrolyte Specific Gravity
Fully charged:
Discharged: less than 1.240
Battery Specifications
BCI Group 26 SMF–5 Battery:
530 Amp Cranking Performance at 0
85 min. Reserve Capacity at 80
2
a
Page 5 - 32
1.250 - 1.280
o
o
F (–17
o
o
F (27
C)
1
Figure 36
1. Positive (+) terminal
2. Negative (–) terminal
Figure 37
Reelmaster
C)
®
5100-D