Lift Circuit Variable Orifice Adjustment - Toro Reelmaster 5100-D Service Manual

Hide thumbs Also See for Reelmaster 5100-D:
Table of Contents

Advertisement

Lift Circuit Variable Orifice Adjustment

Adjustable orifices are adjusted at the factory and
should not require adjustment unless tampered with or
in special situations.
Opening valve increases lift speed. Closing valve slows
lift speed.
NOTE: Adjustment for special operating conditions
should not require more than 1/2 turn of valve in either
direction from initial adjustment.
Front Center Initial Adjustment (Fig. 25)
This adjustment affects the front center (No. 1) cutting
unit only. Loosen set screw. Turn valve clockwise to fully
closed position. Turn valve counterclockwise (open)
2-1/2 turns. Secure adjustment by tightening set screw.
Rear Initial Adjustment (Fig. 26)
Loosen set screw. Turn valve clockwise to fully closed
position. Turn valve counterclockwise (open) 2-1/4
turns. Secure adjustment by tightening set screw.
Adjustments
1. Front center adjustable orifice
1. Rear circuit adjustable orifice
Page 4 - 34
1
Figure 25
1
Figure 26
Reelmaster
®