Main circuit wiring for SINAMICS V70 FSD
Note
For more information about the wiring of the external braking resistor, see Section "Connecting an external braking resistor
(Page 108)".
Note
Filter
A line filter is required so that the system can pass the CE certification (radiated emission test or conducted emission test).
Type E combination motor controller/circuit breaker
You can install a Type E combination motor controller or circuit breaker to protect the system.
For more information about the article numbers of Siemens recommended filters and Type E combination motor
controllers/circuit breakers, see Sections "Line filters (Page 34)" and "Fuse/Type E combination motor controllers and circuit
breakers (Page 32)".
4.4.4
Connecting the 24 V power supply/STO - X6
Control circuit interfaces - drive side
Type
Safe Torque Off (STO) interfaces
Control power input interfaces
Maximum connectable cross-section: 1.5 mm
Maximum cable length: 10 m
Maximum current consumption values without a brake power supply and with a brake power supply are respectively 1 A
1)
and 3 A.
For more information about the 24 VDC power supply, see Section "External 24 VDC power supply (Page 32)".
102
1)
2
Illustration
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018