Siemens SINUMERIK 808D ADVANCED Series Commissioning Manual page 405

Hide thumbs Also See for SINUMERIK 808D ADVANCED Series:
Table of Contents

Advertisement

Par. No.
Name
r0079[0...1]
Torque setpoint
total
Description: Displays the torque setpoint at the output of the speed controller (before clock cycle interpola-
tion).
[0]: Unsmoothed
[1]: Smoothed
r0632
Motor tempera-
ture model, sta-
tor winding
temperature
Description: Displays the stator winding temperature of the motor temperature model.
p0918
Drive Bus ad-
dress
Description: Displays or sets the Drive Bus address for Drive Bus interface on the servo drive.
The address can be set as follows:
Using p0918
Only if the address 00 hex, 7F hex, 80 hex, or FF hex has been set using the address switch.
The address is saved in a non-volatile fashion using the function "copy from RAM to ROM".
A change only becomes effective after a POWER ON.
p1058
Jog 1 speed
setpoints
Description: Sets the speed/velocity for jog 1. Jogging is level-triggered and allows the motor to be incre-
mentally moved.
p1082
Maximum speed
Description: Sets the highest possible speed.
Dependency: p0322
p1083
Speed limit in
positive direction
of rotation
Description: Sets the maximum speed for the positive direction.
p1086
Speed limit in
negative direc-
tion of rotation
Description: Sets the speed limit for the negative direction.
p1120
Ramp-function
generator ramp-
up time
Description: The ramp-function generator ramps-up the speed setpoint from standstill (setpoint = 0) up to the
maximum speed (p1082) in this time.
Dependency: p1082
p1121
Ramp-function
generator ramp-
down time
Description: The ramp-function generator ramps-down the speed setpoint from the maximum speed (p1082)
down to standstill (setpoint = 0) in this time.
Further, the ramp-down time is always effective for OFF1.
Dependency: p1082
p1215
Motor holding
brake configura-
tion
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
Min
Max
-
-
-
-
10
16
0
210000.000
0.000
210000.000
0.000
210000.000
-
0.000
210000.0
00
0.000
999999.000
0.000
999999.000
0
3
Factory setting
Unit
-
Nm
-
°C
10
-
100
rpm
1500.000
rpm
210000.000
rpm
-210000.000
rpm
10.000
s
10.000
s
0
-
Data type
Effective
Can be
changed
Float
-
-
Float
-
-
U16
RE
T
Float
IM
T
Float
IM
T
Float
IM
T, U
Float
IM
T, U
Float
IM
T, U
Float
IM
T, U
I16
IM
T
405

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 808d advanced t

Table of Contents