Drive Basic List On Hmi - Siemens SINUMERIK 808D ADVANCED Series Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D ADVANCED Series:
Table of Contents

Advertisement

Par. No.
Name
Description: Firmware version.
[0]: Firmware version number
[1]: Build increment number
Note:
Index [1] only applies to V70 firmware versions higher than 1.00.
For example, when r29018[0] = 10100 and r29018[1] = 10, the firmware version is displayed as 1.01.00.10
on the HMI.
16.2.2

Drive basic list on HMI

The drive basic list on HMI contains the most frequently used drive parameters for commissioning. You can also view them
through the following operations:
+
Par. No.
Name
p0977
Save all parameters
Description:
Saves all parameters of the drive system to the non-volatile memory. When saving, only the adjustable
parameters intended to be saved are taken into account.
Dependency: p0976
Caution:
Memory card inserted:
The drive parameterization is also saved on the card. Any backed-up data is overwritten!
Notice:
The Control Unit power supply may only be powered down after data has been saved (i.e. after data save
has been started, wait until the parameter again has the value 0). Writing to parameters is inhibited while
saving.
Note:
Parameters saved with p0977 = 10, 11 or 12 can be downloaded again with p0976 = 10, 11 or 12.
p1460[0...n]
Speed controller P gain ad-
aptation speed lower
Description:
Sets the P gain of the speed controller before the adaptation speed range (0 ... p1464). This value corre-
sponds to the basic setting of the P gain of the speed controller without adaptation (p1461 = 100 %).
Dependency: p1461
Note:
When automatically calculating the speed controller, only the motor moment of inertia is taken into account
(p0341). For higher load moments of inertia (p0342 > 1 or p1498 > 0), you are advised to check the speed
controller gain.
p1461[0...n]
Speed controller Kp adapta-
tion speed upper scaling
Description:
Sets the P gain of the speed controller for the upper adaptation speed range (> p1465). The entry is made
referred to the P gain for the lower adaptation speed range of the speed controller (% referred to p1460).
Dependency: p1460
410
Min
Max
Min
0
0.000
0.0
Factory setting
Unit
Max
Factory
Unit
setting
1013
[0] 0
-
999999.0
0.300
Nms/r
00
ad
200000.0 [0]
[%]
100.0
Data type
Effective
Can be
changed
Data type
Effective
U16
IM
Float
IM
Float
IM
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
Can be
changed
T, U
T, U
T, U