4.2.5

Digital input interfaces - X100, X101, X102

Pin assignment
Type
Mini Combicon 10-pin
Cable
Max. length: 10 m
Max. cross-section: 1.5 mm
Inputs
Permissible level (including ripple)
High level: 20.4 V to 28.8 V
Pin
X100 (DIN0)
1
N.C.
2
I0.0
3
I0.1
4
I0.2
5
I0.3
6
I0.4
7
I0.5
8
I0.6
9
I0.7
10
M
Connecting according to the default PLC program
Turning
Milling
Note
End sleeves are necessary if you use two cables per connection.
Fasten the cables to the screw terminals and plug the terminals into interfaces X100, X101 and X102 correctly.
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
(when using one cable per connection)
2
X101 (DIN1)
N.C.
I1.0
I1.1
I1.2
I1.3
I1.4
I1.5
I1.6
I1.7
M
Low level: -3 V to +5 V
X102 (DIN2)
N.C.
I2.0
I2.1
I2.2
I2.3
I2.4
I2.5
I2.6
I2.7
M
Remarks
Not assigned
Digital input
Digital input
Digital input
Digital input
Digital input
Digital input
Digital input
Digital input
External ground