Installation altitude above sea
level
3000
3500
4000
NOTICE
Damage to the motors
For surrounding air temperatures > 55 °C, please contact your local Siemens office.
The standard motors are not suitable for use in corrosive atmospheres, atmospheres with a high salt content, or in outdoor
applications; otherwise, the motors may be damaged.
Torque-speed/power-speed characteristics - SH100
1PH1101-1❑F❑:
n
P
M
N
N
N
[rpm]
[kW]
[Nm]
1500
3.7
24
384
Factors for reducing the torque/power according to EN 60034-6
40 °C
0.86
0.82
0.77
I
U
f
N
N
N
[A]
[V]
[Hz]
10.3
326
53.3
45 °C
0.82
0.79
0.74
U
n
n
max
2
max
[V]
[rpm]
[rpm]
355
4300
10000
50 °C
0.79
0.75
0.71
P
M
I
s6-25%
s6-25%
s6-25%
[kW]
[Nm]
[A]
5.55
36
15
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
I
max
[A]
20.6