7.6
Setting compensation data
7.6.1
Setting software limit switch data
The software limit switches are used to limit the maximum traversing range on each individual axis.
You can set the software limit switches for each axis by configuring parameters 36100 and 36110 under this commissioning
step.
Softkey functions
①
Selects the next axis
②
Selects the previous axis
③
Activates the modified values
④
Resets the value of the selected parameter to default
Setting parameters
No.
Name
36100
POS_LIMIT_MINUS
36110
POS_LIMIT_PLUS
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
⑤
Cancels the last change to the parameter
⑥
Returns to the last step
⑦
Proceeds to the next step
Unit
Range
mm
-
mm
-
Description
- software limit switch
+ software limit switch
217