7.6

Setting compensation data

7.6.1

Setting software limit switch data

The software limit switches are used to limit the maximum traversing range on each individual axis.
You can set the software limit switches for each axis by configuring parameters 36100 and 36110 under this commissioning
step.
Softkey functions
Selects the next axis
Selects the previous axis
Activates the modified values
Resets the value of the selected parameter to default
Setting parameters
No.
Name
36100
POS_LIMIT_MINUS
36110
POS_LIMIT_PLUS
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
Cancels the last change to the parameter
Returns to the last step
Proceeds to the next step
Unit
Range
mm
-
mm
-
Description
- software limit switch
+ software limit switch
217