● Connecting
2.1.5.5
Line filters
Siemens recommends you to use a filter to protect the system from high frequency noise.
The table below lists all filters recommended by Siemens:
SINAMICS V70
Drive vari-
Frame
ant
size
Feed drive
FSA
FSA
FSB
FSB
FSB
FSC
FSC
Spindle
FSB
drive
FSC
FSC
FSD
FSD
34
Recommended filter
Rated input
Rated current
current (A)
(A)
1.5
5
3.8
5
5.8
12
6.6
12
9.8
12
13.8
20
16.5
20
13.2
12
16.2
24
24.5
24
37.3
36
47
74
Wire gauge
Degree of
(AWG)
protection
15 to 13
IP20
IP20
15 to 14
IP20
IP20
IP20
11 to 10
IP20
IP20
15 to 14
IP20
11 to 10
IP20
10 to 9
IP20
7 to 6
IP20
5 to 4
IP20
Article number
6SL3203-0BE15-0VA0
6SL3203-0BE21-2VA0
6SL3203-0BE22-0VA0
6SL3203-0BE21-2VA0
6SL3000-0HE21-0AA0
6SL3000-0BE21-6DA0
6SL3000-0BE23-6DA1
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018