Siemens SINUMERIK 808D ADVANCED Series Commissioning Manual page 409

Hide thumbs Also See for SINUMERIK 808D ADVANCED Series:
Table of Contents

Advertisement

Par. No.
Name
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
p1658
Current setpoint
filter 1 denomi-
nator natural
frequency
Description: Sets the denominator natural frequency for current setpoint filter 1 (PT2, general filter).
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
p1659
Current setpoint
filter 1 denomi-
nator damping
Description: Sets the denominator damping for current setpoint filter 1.
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
p1660
Current setpoint
filter 1 numerator
natural frequen-
cy
Description: Sets the numerator natural frequency for current setpoint filter 1 (general filter)
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
p1661
Current setpoint
filter 1 numerator
damping
Description: Sets the numerator damping for current setpoint filter 1.
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
r2114[0...1]
System runtime
total
Description: Displays the total system runtime for the drive unit.
The time comprises r2114[0] (milliseconds) and r2114[1] (days).
After r2114[0] has reached a value of 86.400.000 ms (24 hours) this value is reset and r2114[1] is incre-
mented.
[0] = Milliseconds
[1] = Days
p2153
Speed actual
value filter time
constant
Description: Sets the time constant of the PT1 element to smooth the speed/velocity actual value.
The smoothed actual speed/velocity is compared with the threshold values and is only used for messages
and signals.
p29000
Motor type se-
lection
Description: Motor type number is printed on the motor rating plate as motor ID. For a motor with an incre-
mental encoder, you need to manually input the parameter value, ranging from 18 to 39. For a motor with an
absolute encoder, the drive reads the parameter value automatically, ranging from 10009 to 10048.
p29002
BOP operating
display selection
Description: BOP operating display selection.
0: Actual speed
1: DC voltage
2: Actual torque
r29018[0...1
Firmware ver-
]
sion
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
Min
Max
0.5
16000.0
0.001
10.000
0.5
16000.0
0.000
10.000
-
-
0
1000000
0
54251
0
2
-
-
Factory setting
Unit
1999.0
Hz
0.700
-
1999.0
Hz
0.700
-
-
-
0
ms
-
-
0
-
-
-
Data type
Effective
Can be
changed
Float
IM
T, U
Float
IM
T, U
Float
IM
T, U
Float
IM
T, U
U32
-
-
Float
IM
T, U
U16
IM
T
U16
IM
T, U
U32
-
-
409