4. Connecting Cables
Power Cord Connection
Power
distribution
unit#1
Power
distribution
unit#0

When the DC Power Type Is Used

Connect the power cords to the ETERNUS DX.
The following procedure explains how to connect a DC power cord.
IMPORTANT
• One 40A fast-trip double-pole DC-rated circuit breaker must be located between each power supply unit
of the ETERNUS DX and each DC power supply device.
• Do not use any power cord other than the one provided with the ETERNUS DX. Also, do not use it with
other devices or purposes.
The power cord that is provided has been designed and tested for safe connection with the ETERNUS DX.
• To help with DC power cord management and prevent incorrect power cord connection, attach labels to
the DC power cords and make a note of the connection origins and destinations.
• When connecting DC power cords, check the connector orientation and then firmly push it all the way in.
When disconnecting DC power cords, depress the tab, then pull out the connector.
1
Stop power from a DC power supply device by using a circuit breaker.
2
Connect the DC power cords to the ETERNUS DX.
IMPORTANT
Each enclosure has two (PSU#0 and PSU#1) power supply units. Make sure that both of the power
supply units are connected with DC power cords.
Connect the DC power cord plugs to the power inlets of the power supply units.
3
Connect the DC power cords to the DC power supply devices via circuit breakers.
Attach the required connector type to the DC power cords for circuit breaker connection (a GND connector
can be directly attached to a DC power supply device).
An external view of a DC power cord is shown below.
AC input cables
Connect to power outlets.
63
Configuration Guide (Basic)