Fujitsu ETERNUS DX S5 Series Configuration Manual page 125

Hybrid storage systems
Hide thumbs Also See for ETERNUS DX S5 Series:
Table of Contents

Advertisement

6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)
The recommended drive configuration of the RAID group is shown as follows:
-
Select drives with the same capacity and speed.
Select SSDs with the same type (SSD-M/SSD-L/SSD-M SED/SSD-L SED).
-
Select the same sector format of drives (AF-compliant/non-AF-compliant).
-
-
If the host connection environment does not support AF, select non-AF-compliant drives. Refer to
"Create RAID Group" in "ETERNUS Web GUI User's Guide" for details.
When "High Performance (RAID1+0) " or "Mirroring (RAID1)" is selected for the RAID level, allocate the
-
drives (mirroring pair drives) by dividing them into two or more connection lines (for the ETERNUS
DX500 S5/DX600 S5/DX900 S5).
When "High Capacity (RAID5)", "High Reliability (RAID6)", or "High Reliability (RAID6-FR)" is selected for
-
the RAID level, allocate the drives (multiple drives configuring a striping) by dividing them into two or
more connection lines (for the ETERNUS DX500 S5/DX600 S5/DX900 S5).
Note that these requirements are not applied to the ETERNUS DX60 S5/DX100 S5/DX200 S5.
-
The procedure to create a TPP by selecting drives manually is as follows:
1
Click [Create] in [Action].
The [Create Thin Provisioning Pool] screen appears.