7. Host Interface Management
Modify Port Parameters
Note
• Multiple selections can be made from FC ports that have the same SFP type and port mode. Note
that multiple FC ports can also be selected if the SFP types are one of the following combinations.
- A mix of "16G SFP+(SMF)" and "16G SFP+(MMF)"
- A mix of "SFP+(SMF)", "SFP+(MMF)", "Unknown", and "Unmount"
• Multiple ports can be set with the same or with different parameters in a single operation. To set
parameters to multiple ports, select the target ports and specify the parameters for each port.
After the specification is complete, click the [Modify] button.
2
Set the parameters for all of the selected ports.
The following explains how to change the port parameters when the port mode is "CA".
The main setting items are as follows.
Port Settings
Port
-
-
Connection
Set Loop ID
-
Loop ID
-
-
Transfer Rate
3
Click the [Modify] button.
Caution
If the Loop ID is changed while a server is operating, reboot the server immediately. If the server is
operated without being rebooted, a warning message may appear or a system failure may occur.
4
A confirmation screen appears. Click the [OK] button.
Setting of the FC port parameters starts.
5
Click the [Done] button to return to the [FC Port] screen.
138