ENGINE MANAGEMENT MODULE (EMM)

EMM SERVICING

EMM SERVICING
IMPORTANT:
If a new EMM is being installed,
refer to EMM Transfer on p. 65.

Removal

Disconnect cooling hoses from EMM.
Disconnect J1-A connector.
Remove two EMM retaining screws. Remove
EMM.
1
1. Cooling hose connections
2. EMM mounting screws
66

Installation

Installation is the reverse of removal. Pay close
attention when performing the following tasks.
Make sure isolator mount is in place on recoil
starter housing. Slide pin at rear EMM into posi-
tion on isolator mount.
1
2
1. Isolator mount
2. Pin
IMPORTANT:
clock-wise to start the threads and clockwise to
tighten. Failure to follow this procedure can dam-
007396
age the threads of the housing.
Tighten screws securely.
Install harness connector and cooling hoses.
Secure hoses with tie straps.