Tilt/Trim Relay Test - BRP Evinrude E-TEC Series Service Manual

Hide thumbs Also See for Evinrude E-TEC Series:
Table of Contents

Advertisement

ELECTRICAL AND IGNITION

TILT/TRIM RELAY TEST

TILT/TRIM RELAY TEST
The tilt and trim (TNT) module contains the cir-
cuitry and relays required for power trim and tilt
operation.
1
1. Tilt and trim module
The tilt and trim switch provides B+ input to
green/white or blue/white wire of the TNT module.
Operation
The relay activates when B+ input from the switch
is supplied to terminal 86 of the internal relays.
Terminal 87a connects to ground (B–).
Terminal 87 connects to B+.
Terminal 30 connects TNT motor.
Terminals 87a and 30 are connected when relay is
not activated. This supplies ground (B–) connec-
tion to TNT motor.
Terminals 87 and 30 are normally open. B+ is
applied to terminal 30 when relay is activated.
This supplies ground B+ connection to TNT motor.
Refer to Tilt and Trim Module Diagram.
100
Test Procedure
Make sure red and black wires are connected to
12 V battery power supply.
Set voltmeter to 12 VDC scale. Connect test leads
to terminals "A" and "B" of TNT motor connector.
Use a wire jumper to alternately connect B+ to ter-
minals "1" and "2" of tilt and trim switch connector.
The meter must indicate battery voltage (12 V)
with B+ connected to either terminal.
007356
5
Tilt and Trim Module Diagram
1. Green/white wire
2. Blue/white wire
3. B+, red wire
4. B–, black wire
5. TNT motor connector
6. TNT switch connector
3
4
1
2
6
002063