Recoil Starter Removal - BRP Evinrude E-TEC Series Service Manual

Hide thumbs Also See for Evinrude E-TEC Series:
Table of Contents

Advertisement

RECOIL STARTER
REMOVAL
WARNING
To prevent accidental starting while ser-
vicing, twist and remove all spark plug
leads.
Remove all electrical connectors from the recoil
starter housing.
1
1. Electrical connectors
Remove cooling hose from the EMM.
1
1. Cooling hose
Remove two EMM mounting screws and move the
EMM to the side.
Remove the vapor separator vent hose and wiring
1
from the retainers on the recoil starter housing.
007241
1. Vapor separator vent hose
2. Wiring
Remove three recoil starter mounting screws.
Remove recoil starter assembly.
007222
1
1. Screws
MANUAL STARTER

RECOIL STARTER REMOVAL

007223
1
2
007220
1
007223
14
281