MANUAL STARTER

RECOIL STARTER INSTALLATION

RECOIL STARTER
INSTALLATION
Position the wiring in the retaining bracket of recoil
starter housing.
2
1
2. Wiring
3. Retaining bracket
Install recoil starter assembly. Tighten mounting
screws to a torque of 31 to 48 in. lbs. (3.5 to 5.5
N·m).
1
1. Screws
282
Install stator connector in retainer groove of starter
housing.
1
1. Stator connector
NOTICE
To prevent damage to wiring from
rotating flywheel, make sure stator connector
007227
is securely fastened to the starter housing.
Position the vapor separator vent hose and wiring
in the retainers on the recoil starter housing as
shown.
1
1. Retainers
007223
007229
1
007230

Advertisement