Static Ignition Test - BRP Evinrude E-TEC Series Service Manual

Hide thumbs Also See for Evinrude E-TEC Series:
Table of Contents

Advertisement

Static Ignition Test

Perform the static ignition test using Evinrude
Diagnostics software and an inductive timing light.
IMPORTANT:
Do NOT perform static tests using
Diagnostic Power Supply Tool, P/N 587005, with
internal 9 volt batteries only. This will produce
false results. Refer to Communication on p. 58.
IMPORTANT:
DO NOT use a spark checker
tool. Radio Frequency Interference (RFI) gener-
ated by the arcing current can cause erratic EMM
operation.
The outboard must NOT be running and the emer-
gency stop switch lanyard must be installed.
Static Tests Screen
Connect timing light pickup to the secondary cir-
cuit (spark plug lead) of the cylinder being tested.
Activate test and observe timing light strobe for
consistent flash.
IMPORTANT:
coil with 12 V battery power on the system voltage
(55 V) circuit. An inductive probe with low sensitiv-
ity may not be able to detect the signal.
2
1. Timing light pick-up
2. Spark plug lead
Results:
No spark on one or more cylinders:
Inspect or replace spark plugs
Refer to Ignition Control Circuit Tests on
p. 77
Refer to Ignition Coil Tests on p. 77
Steady spark on all cylinders:
Refer to Running Ignition Tests on p. 76 and
DYNAMIC TESTS on p. 70.
008140
SYSTEM ANALYSIS
IGNITION OUTPUT TESTS
This test is operating the ignition
1
5
007398
75