Haccp; Printing Reports - Henny Penny Electric SpaceSaver Plus 610 Operating Manual

Table of Contents

Advertisement

Space$aver™

HACCP

Printing reports

The Space$aver™ stores up to 200 HACCP reports,
depending on the number of program stages.
A laptop or a serial
1
mini-printer
is used
to produce the
reports via the RS
232 serial interface.
The maximum
Asterisk=
length of the RS 232
Programme name
Record has been
Record No.
connecting cable
printed previously
must not exceed 3 m.
HACCP
000
*Baked ham
Use the Left-Select
22.01.2003
08:15
button to call up the
Back
Print
menu in the display.
Recording start time
Cooking date
Select HACCP with
the CombiDial and
press to confirm.
The display shows
the last report (latest)
record entered
marked as "000".
The higher the
number, the older
the report.
Breaks can occur between the report numbers in the HACCP
memory. These are caused by cooking programs that take less
than one minute, since these are not logged.
Press the Right-Select button to print the selected report.
1.Serial printer, 40 columns, RS 232 interface,
Setting: 9600, N, 8.1