Resetting (Initializing) Control Electronics; Measuring Mode - Henny Penny Electric SpaceSaver Plus 610 Operating Manual

Table of Contents

Advertisement

Space$aver™
Resetting (initializing) the
control electronics
22.01.03
Menu

Measuring mode

70
Program running errors (e.g. specified settings were not kept);
can be corrected by resetting (initializing) the electronic
controls. This resets the electronics to the start mode. The
stored program will not be deleted.
To reset the system, press and hold the On/Off button (with the
appliance switched on) for approx. 8 seconds until the control
electronics turn off.
The electronics will switch back on after approx. 10 seconds.
08:07
The appliance is now in the start mode (standby) and the
T/SRH
following appears in the start screen display
If when resetting the control electronics the
"on/off" button is accidentally pressed for longer than 8 sec.
with the appliance switched off, the electronics change into the
measuring mode.
To deactivate the measuring mode again, the "on/off" button
must be pressed for 20 sec. with the appliance switched off.
Then the control electronics change to the normal operating
mode again.
Electric Space$aver™
Errors