Errors - Henny Penny Electric SpaceSaver Plus 610 Operating Manual

Table of Contents

Advertisement

Errors

Error message
No water
Unit overheated
High limit
Fan high limit
Electronics too warm
Electronics too hot
Food probe defective
Chamber temperature
probe defective
Risk of freeze damage
Battery empty
Carry out the
configuration program.
Drain probe defective
HW-Fail
Temp UREF0 too high
CD = Customer service department
Cause
Water valve closed,
appliance defective
Appliance defect
Appliance defect
Fan overheating.
Defective cooling
Defective cooling, ambient
temperature too high
See above
Probe defective
Probe defective
Temperature <32°F (0°C )
Backup battery empty
Normal operating life 8 years
The electronics were replaced
without essential configuration
being carried out.
Temperature measurement for
drain water defect.
Cooling water is switched on
intermittantly. Otherwise,
normal operation possible
Core-temperature probe or
keypad defective
Electric Space$aver™
Space$aver™
Correction
Water valve open
Contact customer service
Stop using appliance; Call Certified Sevice
Agent
Call Certified Sevice Agent
Allow to cool down. Appliance can be used.
Call Certified Sevice Agent
Appliance can be used, set a lower temperature.
Call Certified Sevice Agent
Appliance cannot be used any more
Call Certified Sevice Agent
Cooking programs without core temperature can
still be used. Call Certified Sevice Agent
Cooking programs without core temperature can
still be used. Core temperature probe is used as a
replacement sensor. Do not introduce core
temperature sensors into the products. The core
temperature probe must remain inside the oven
chamber. Call Certified Sevice Agent
Only operate the appliance at temperatures of
<32°F (0°C ) and above. Freezing may lead to
cracks in pipes and components.
Settings are lost if the power fails. Otherwise,
normal operation possible. Call Certified Sevice
Agent
Call Certified Sevice Agent Carry out the
configuration program.
Call Certified Sevice Agent
Replace core-temperature probe or keypad,
call customer service
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Electric spacesaver 605Ecs-605Esc-610

Table of Contents