7 Troubleshooting

7.1 Emergency mode

INFORMATION

7.2 Causes of errors and remedies

Fault no.
Error message displayed
694
• Cooking zone sensor is
defective
695
699
• Internal core temperature
sensor is defective
700
714
716
If a fault occurs during operation, the error number and error message
are displayed.
Use CombiDoctor to analyse the cause, if the cooking result or cleaning
with WaveClean is different from that expected, and if an error
message is not displayed.
Emergency programs handle the limited further operation of the appliance until
servicing. Deviating cooking results and temperature deviations are possible.
In order to allows limited use in case of error, the unit has several
different emergency programs. Emergency operation is activated
automatically and displayed. After elimination of the error indicated, the
controls switch back into normal operation automatically. A reset is not
necessary.
Description
The internal core temperature
sensor takes over the function of
the defective cooking zone sensor.
The internal core temperature
sensor in the cooking zone is
deactivated.
Operating instructions
Troubleshooting
Measure to be taken
• Insert the internal core temperat-
ure sensor into its holder.
• A different cooking result may oc-
cur.
• Contact Customer service.
• If possible, use the external core
temperature sensor (optional).
• Select another cooking program.
• Contact Customer service.