PNU
Description
P803
Baud rate for G-SST3
*
1
300 baud
(G172)
2
600 baud
(G174)
3
1200 baud
4
2400 baud
5
4800 baud
6
9600 baud
7
19200 baud
8
38400 baud
9
56700 baud
11
93750 baud
13
187500 baud
P804
Source for transmit data for G-SST3
*
Selection of connectors to be transferred as transmit data via basic
(G172)
converter interface 3
(G174)
When USS protocol (P800=2) is selected:
i001:
Selection for word 1
i002:
Selection for word 2
...
i016:
Selection for word 16
When peer-to-peer (P800=5) is selected:
i001:
Selection for word 1
i002:
Selection for word 2
...
i005:
Selection for word 5
i006:
Not used
...
i016:
Not used
Applicable settings:
0 = connector K0000
1 = connector K0001
etc.
P805
Options for G-SST3
i001:
0 = Bus terminator OFF
(G172)
1 = Bus terminator ON
(G174)
i002:
0 = Bit 10 of the 1
by PLC".
1 = Bit 10 of the 1
PLC", i.e. when bit 10 = 0, all other bits of the 1
as well as receive words 2 to 16, are not written to connectors
K9001 to K9016, or to binectors B9100 to B9915. All these
connectors and binectors retain their old values.
P806
USS bus address for G-SST3
*
This parameter is functional only when P800=2 (USS protocol). Address via
(G172)
which the unit can be addressed in USS bus operation.
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
st
receive word does not function as "Control
st
receive word does function as "Control by
st
receive word,
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
1 to 13
Ind: None
1
FS=13
Type: O2
All connector
Ind: 16
numbers
FS=
1
i001: 32
i002: 167
i003: 0
i004: 33
i005-i016: 0
Type: L2
0 to 1
Ind: 2
1
FS=0
Type: O2
0 to 30
Ind: None
1
FS=0
Type: O2
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline