PNU
Description
P666
2nd source for control word 1, bit7
*
(0 → 1 transition=acknowledge; ORed with 1
BDS
(G180)
P667
3rd source for control word 1, bit7
*
(0 → 1 transition=acknowledge; ORed with 1
BDS
(G180)
P668
Source for control word 1, bit8
*
(1=inching bit0)
BDS
(G180)
P669
Source for control word 1, bit9
*
(1=inching bit1)
BDS
(G180)
P671
Source for control word 1, bit11
*
(0=pos. direction of rotation disabled, 1=pos. direction of rotation enabled)
BDS
(G180)
P672
Source for control word 1, bit12
*
(0= neg. direction of rotation disabled, 1= neg. direction of rotation enabled)
BDS
(G180)
P673
Source for control word 1, bit13
*
(1=raise motorized potentiometer)
BDS
(G180)
P674
Source for control word 1, bit14
*
(1=lower motorized potentiometer)
BDS
(G180)
P675
Source for control word 1, bit15
*
(0=external fault, 1=no external fault)
BDS
(G180)

Control word 2

P676
Source for control word 2, bit16
*
(select function data set bit 0)
BDS
(G181)
P677
Source for control word 2, bit17
*
(select function data set bit 1)
BDS
(G181)
P680
Source for control word 2, bit20
*
(select fixed setpoint 0)
BDS
(G181)
P681
Source for control word 2, bit21
*
(select fixed setpoint 1)
BDS
(G181)
P684
Source for control word 2, bit24
*
(0=n controller speed droop disabled, 1=enabled)
BDS
(G181)
P685
Source for control word 2, bit25
*
(0=n controller disabled, 1=n controller enabled)
BDS
(G181)
P686
Source for control word 2, bit26
*
(0=external fault 2, 1=no external fault 2)
BDS
(G181)
P687
Source for control word 2, bit27
*
(0=master drive, speed control, 1=slave drive, torque control)
BDS
(G181)
P688
Source for control word 2, bit28
*
(0=external alarm 1, 1=no external alarm 1)
BDS
(G181)
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
st
rd
and 3
sources for bit7)
st
nd
and 2
sources for bit7)
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
10-69