Setting Values For Configuring The Setpoint Processing Function And Ramp-Function Generator; P632 Source For Variable Positive Limitation At Ramp-Function Generator Output; P633 Source For Variable Negative Limitation At Ramp-Function Generator Output; P631 Source For Setting Value For Speed Controller Integrator - Siemens 6RA70 Series Instructions Manual

Microprocessor-based converters from 15a to 1680a for variable speed dc drives
Hide thumbs Also See for 6RA70 Series:
  • Faq (4 pages)
Table of Contents

Advertisement

PNU
Description
P627
Source for input of D element
*
Selection of connector to be injected as the input signal for the D element
(G152)
0 = connector K0000
1 = connector K0001
etc.
P628
Source for input of band-stop filter 1
*
Selection of connector to be injected as the input signal for band-stop filter 1
(G152)
0 = connector K0000
1 = connector K0001
etc.
P629
Source for band-stop filter 2
*
Selection of connector to be injected as the input signal for band-stop filter 2
(G152)
0 = connector K0000
1 = connector K0001
etc.
Speed controller droop
P630
Source for influencing quantity for speed droop
*
Selection of connector to be injected as the influencing quantity
(G151)
0 = connector K0000
1 = connector K0001
etc.
Setting the speed controller I component
Function: When the binector selected in P695 switches state from log. "0" to log. "1", the I component of the speed controller is set to the
value of the connector selected in P631.
With this function it is possible, for example, to use the same signal (binector) to control controller enabling commands and
setting of the I component.
P631
Source for setting value for speed controller integrator
*
Selection of connector to be injected as the setting value for the I
component
(G152)
0 = connector K0000
1 = connector K0001
etc.

Setting values for configuring the setpoint processing function and ramp-function generator

Limitation at ramp-function generator output (setpoint limitation)
(see also Section 8, Sheet G136 of Operating Instructions 6RX1700-0AD**)
The effective limitations are:
Upper limit:
Minimum value of P300 and the four connectors selected with P632
Lower limit:
Maximum value of P301 and the four connectors selected with P633
Note:
The limiting values for both the positive and negative setpoint limits can have a positive or negative sign. The negative setpoint
limit, for example, can therefore be parameterized to a positive value and the positive setpoint limit to a negative value.
P632
Source for variable positive limitation at ramp-function generator
*
output
Selection of connectors to be injected at the variable positive limitation at
(G137)
the ramp-function generator output (setpoint limitation).
0 = connector K0000
1 = connector K0001
etc.
P633
Source for variable negative limitation at ramp-function generator
*
output
Selection of connectors to be injected at the variable negative limitation at
(G137)
the ramp-function generator output (setpoint limitation).
0
= connector K0000
...
8
= connector K0008
= value as set in parameter P632 ∗ ( − 1)
9
10 = connector K0010
etc.
10-64
Value range
[Unit]
Steps
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
FS=178
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=179
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=177
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=162
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=9
P051 = 40
Type: L2
Offline