PNU
Description
P634
Source for limitation input at ramp-function generator output
*
Selection of connectors which must be added up to provide the limitation
input at the ramp-function generator output (setpoint limitation).
(G137)
0 = connector K0000
1 = connector K0001
etc.
P635
Source for ramp-function generator setpoint
*
Selection of connector to be injected as the ramp-function generator
FDS
setpoint
0 = connector K0000
(G135)
1 = connector K0001
etc.
P636
Source for reduction signal for ramp-function generator times
*
Selection of connector to be injected as the reduction signal for the ramp-
function generator times
(G136)
i001 acts on ramp-up and ramp-down time (P303, P304)
i002 acts on lower and upper transition roundings (P305, P306)
i003 acts on ramp-up time (P303)
i004 acts on ramp-down time (P304)
i005 acts on lower transition rounding (P305)
i006 acts on upper transition rounding (P306)
0 = connector K0000
1 = connector K0001
etc.
P637
Source for selection of "Ramp-function generator setting 2"
*
Selection of binector to control switchover to "Ramp-function generator
BDS
setting 2".
With a log. "1" signal at the binector, ramp-function generator parameter set
(G136)
2 (P307 - P310) is selected. This function has a higher priority than the
ramp-up integrator function.
0 = binector B0000
1 = binector B0001
etc.
P638
Source for selection of "Ramp-function generator setting 3"
*
Selection of binector to control switchover to "Ramp-function generator
BDS
setting 3".
With a log. "1" signal at the binector, ramp-function generator parameter set
(G136)
3 (P311 - P314) is selected. This function has a higher priority than the
ramp-up integrator function.
0 = binector B0000
1 = binector B0001
etc.
P639
Source for the ramp-function generator setting values
*
Selection of the connectors that are connected as the ramp-function
generator setting values.
(G136)
i001
Setting value for the ramp-function generator output in state log.
"1" of the binector selected via P640
i002
Setting value for the ramp-function generator output if the drive
is not in state "Operating" (B0104=0) and the binector selected
via P640 is in state log. "0"
[i002 only available with SW 1.6 and later]
0 = Connector K0000
1 = Connector K0001
etc.
P640
Source for selection of "Set ramp-function generator"
*
Selection of binector to control the "Set ramp-function generator" function
BDS
0 = binector B0000
(G136)
1 = binector B0001
etc.
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 2
numbers
FS=
1
i001: 190
i002: 0
Type: L2
All connector
Ind: 4
numbers
FS=194
1
Type: L2
All connector
Ind: 6
numbers
FS=1
1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All connector
Ind: 2
numbers
FS=167
1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
≥ off-line
P052 = 3
P051 = 40
Offline
10-65