P615 Source For Emf Controller Setpoint; P616 Source For Actual Emf Controller Value; Configuring Of Injection Of Acceleration Value; Speed Controller, Setpoint/Actual Value Deviation - Siemens 6RA70 Series Instructions Manual

Microprocessor-based converters from 15a to 1680a for variable speed dc drives
Hide thumbs Also See for 6RA70 Series:
  • Faq (4 pages)
Table of Contents

Advertisement

PNU
Description
P615
Source for EMF controller setpoint
*
Selection of connectors to be injected as the EMF controller setpoint. The
(G165)
connectors selected in the four indices are added.
0 = connector K0000
1 = connector K0001
etc.
P616
Source for actual EMF controller value
*
Selection of connector to be injected as the actual EMF controller value
(G165)
0 = connector K0000
1 = connector K0001
etc.

Configuring of injection of acceleration value

P619
Source for acceleration injection value
*
Selection of connector to be applied as the acceleration injection value
0 = connector K0000
(G153)
1 = connector K0001
etc.
Speed controller

Speed controller, setpoint/actual value deviation

Function:
The connectors selected in parameters P621 and P622 are added and those selected in P623 and 624 subtracted
P620
Source for speed controller setpoint/actual value deviation
*
Selection of connector to be injected as the control deviation
(G152)
0 = connector K0000
1 = connector K0001
etc.
P621
Source for speed controller setpoint
*
0 = connector K0000
1 = connector K0001
(G152)
etc.
P622
Source for speed controller setpoint
*
0 = connector K0000
1 = connector K0001
(G152)
etc.
P623
Source for actual speed controller value
*
0 = connector K0000
1 = connector K0001
(G152)
etc.
P624
Source for actual speed controller value
*
0 = connector K0000
1 = connector K0001
(G152)
etc.
Speed controller: Filtering of setpoint and actual value, band-stop filters
P625
Source for speed controller setpoint
*
Selection of connector to be injected as the input signal for speed setpoint
FDS
filtering
0 = connector K0000
(G152)
1 = connector K0001
etc.
P626
Source for actual speed controller value
*
Selection of connector to be injected as the input signal for actual speed
FDS
value filtering
(G152)
0 = connector K0000
1 = connector K0001
etc.
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 4
numbers
FS=
1
i001: 289
i002: 0
i003: 0
i004: 0
Type: L2
All connector
Ind: None
numbers
FS=286
1
Type: L2
All connector
Ind: None
numbers
FS=191
1
Type: L2
All connector
Ind: None
numbers
FS=165
1
Type: L2
All connector
Ind: None
numbers
FS=176
1
Type: L2
All connector
Ind: None
numbers
FS=174
1
Type: L2
All connector
Ind: None
numbers
FS=179
1
Type: L2
All connector
Ind: None
numbers
FS=0
1
Type: L2
All connector
Ind: 4
numbers
FS=170
1
Type: L2
All connector
Ind: 4
numbers
FS=167
1
Type: L2
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline