PNU
Description
r011
Display of status of binary outputs
Representation on operator panel (PMU):
(G112)
(G117)
Segment ON:
Segment OFF:
Display of status of binary output terminals:
Segment or bit
0 ..... Terminal 46
1 ..... Terminal 48
2 ..... Terminal 50
3 ..... Terminal 52
7 ..... Terminal 109/110 (relay contact for line contactor)
Display of overloading of binary outputs:
Segment or bit
8 ..... Terminal 46
9 ..... Terminal 48
10 .... Terminal 50
11 .... Terminal 52
12 .... Terminal 26 (15V output)
13 .... Terminal 34, 44 and/or 210 (24V output)
r012
Motor temperature
Display of motor temperature when a KTY 84 temperature sensor is
(G185)
connected (P490.x=1).
A value of "0" is always output in r012 when a PTC thermistor or no
temperature sensor is installed.
i001:
Motor temperature 1 (sensor at terminals 22 / 23)
i002:
Motor temperature 2 (sensor at terminals 204 / 205)
r013
Heatsink temperature
Display of heatsink temperature
r014
Temperature rise
i001:
Calculated motor temperature rise (see P114)
i002:
Calculated thyristor temperature rise (see P075)
r015
Display of line voltage (armature)
(generated as arithmetic rectification average, RMS value display applies to
sinusoidal voltage, average over 3 line-to-line voltages)
r016
Display of line voltage (field)
(generated as arithmetic rectification average, RMS value display applies to
sinusoidal voltage)
r017
Display of line frequency
r018
Display of firing angle (armature)
(G163)
r019
Display of actual armature current
The internal actual armature current value is displayed (arithmetic average
(G162)
over the last 6 current peaks in each case)
r020
Display of the absolute value of armature current setpoint
(G162)
r021
Display of torque setpoint after torque limitation
∧ 0.1% of rated motor torque (=rated motor armature current
=
Steps: 1
(G160)
(P100) * magnetic flux at rated motor field current (P102))
10-8
15
14
13
12
11
10
9
7
6
5
4
3
2
1
0
Corresponding terminal is activated
(HIGH level is applied) or overloaded or short-circuited
Corresponding terminal is not activated
(LOW level is applied) or not overloaded or not short-
circuited
Value range
[Unit]
Steps
8
-58 to +200
[°C]
1°C
-47 to +200
[°C]
1°C
0.0 to 200.0
[%]
0.1%
0.0 to 2800.0
[V]
0.1V
0.0 to 800.0
[V]
0.1V
0.00 to 120.00
[Hz]
0.01Hz
0.00 to 180.00
[degrees]
0.01degrees
-400.0 to 400.0
[% of P100]
0.1% of P100
0.0 to 300.0
[% of P100]
0.1% of P100
-400.0 to 400.0
[%]
0.1% (see column on
left)
SIMOREG DC Master Base Drive Panel Operating Instructions
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
Type: V2
Ind: 2
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: 2
P052 = 3
Type: O2
Ind: None
P052 = 3
Type: O2
Ind: None
P052 = 3
Type: O2
Ind: None
P052 = 3
Type: O2
Ind: None
P052 = 3
Type: O2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2