PNU
Description
P689
Source for control word 2, bit29
*
(0=external alarm 2, 1=no external alarm 2)
BDS
(G181)
P690
Source for control word 2, bit30
*
(0=select Bico data set 1, 1=select Bico data set 2)
(G181)
P691
Source for control word 2, Bit31
*
Main contactor checkback signal:
BDS
(0 = main contactor dropped out, 1 = main contactor picked up)
(G181)
This control input is intended as a means of looping an auxiliary contact of
the main contactor into the device control.
During the Power ON routine, this signal must switch to "1" within the time
period set in P095. If it does not, or it disappears during operation, fault
message F004 with fault value 6 is activated.
P691 = 0: Bit 31 of control word 2 is inoperative.
(This setting of P691 is always active, regardless of whether
control word 2 is input in word mode [P649 = 9] or bit mode
[P649 <> 9])
P691 = 1: Bit 31 of control word 2 is inoperative.
(This setting of P691 is active only when control word 2 is input
in bit mode, i.e. when P649 <> 9)

10.36 Further configuring measures

P692
Source for selection of injection of standstill field
*
Selection of binector to control injection of the standstill field ("0" state =
BDS
inject standstill field)
(G166)
Note:
The delay time set in P258 is not effective when this function is
active.
0 = binector B0000
1 = binector B0001
etc.
P693
Source for selection of enabling command for EMF controller
*
Selection of binector which is to control enabling of the EMF controller
BDS
0 = binector B0000
(G165)
1 = binector B0001
etc.
P694
Source for selection of enabling command for "Torque limit
*
switchover"
BDS
Selection of binector which is to control enabling of the "Torque limit
switchover" function (1=enable, see also Sheet G160 in Section 8 of
(G160)
Operating Instructions 6RX1700-0AD** and P180 to P183)
0 = binector B0000
1 = binector B0001
etc.
P695
Source for selection of "Set speed controller I component" function
*
Selection of binector to control the "Set I component" function
BDS
0 = binector B0000
1 = binector B0001
(G152)
etc.
When the binector selected in P695 switches from log. "0" to log. "1", the I
component of the speed controller is set to the value of the connector
selected in P631.
With this function it is possible, for example, to use the same signal
(binector) to control controller enabling commands and setting of the I
component.
10-70
Value range
[Unit]
Steps
All binector numbers
1
All binector numbers
1
[SW 1.8 and later]
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
SIMOREG DC Master Base Drive Panel Operating Instructions
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
SIEMENS Energy & Automation