7. Press the F1 (R-BUS) to display the DIF-AT's settings.
8. Set INPUT SELECT to TDIF.
9. Press F6 (EXIT).
10. Press PAGE until "Proj" appears above F3.
11. Press F3 (Proj)—the PROJECT PARAMETER screen
12. Set MASTER CLOCK to the R-BUS jack.
13. Press F6 (EXIT).
14. Press F5 (MIDI) to display the MIDI PARAMETER
15. Set MMC MODE to MASTER.
16. Press F6 (EXIT).
17. Press F6 (SYNC)—the SYNC PARAMETER screen appears.
18. Set SYNC MODE to EXT and set the EXT SYNC SOURCE parameter to R-BUS.

ADA-7000 Settings

INPUT SENS 1-8
Each INPUT SENS parameter sets the input sensitivity of the corresponding ADA-7000
input jack—changing a parameter's value is the same thing as turning the
corresponding input sensitivity knob on the front panel of the ADA-7000.
FRONT PANEL CONTROL
You can disable front-panel control of the ADA-7000 so that it can be set only from the
the VS-2400CD. To do this turn FRONT PANEL CONTROL off. If you want to retain
control of the ADA-7000 in both places, leave FRONT PANEL CONTROL on.
When front-panel control of the ADA-7000 is turned on, the values reflect by the
position of its knobs may not agree with its actual current values, as shown on its
R-BUS REMOTE CONTROL screen.
PHANTOM +48V 1-8
Turn on an input jack's PHANTOM +48V 1-8 when you need to supply phantom power
to a condenser mic connected to the input.
Turn a jack's phantom power on only when the device—typically a condenser mic—
connected to the jack requires phantom power. Activating phantom power when other
devices are connected to the jack may result in damage to the connected device.