Table 25 SSCOP Timers (continued)
SSCOP Timer
Description
No-Response
Maximum time between receipt of a STAT PDU in an active
connection.
CC
The connection control timer determines the time between
transmission of BGN, END, or RS PDUs, as long as an
acknowledgment PDU has not been received.
For stability, make the timer No-Response greater than timer Keep-Alive,
and make timer No-Response greater than timer Poll. Also, make timer
No-Response and timer CC greater than the round trip delay.
SSCOP Configuration Parameters
Table 26 shows the SSCOP Configuration Parameters displayed by the
command.
.
Table 26 SSCOP Configuration Parameters
SSCOP
Parameter
Description
MaxCC
Maximum value for the state variable VT(CC), corresponding to
the maximum number of transmissions of a BGN, END, or RS
PDU.
MaxPD
Maximum acceptable value for the state variable VT(PD) before
sending a POLL PDU and resetting VT(PD) to zero.
MaxSTAT
Maximum number of list elements permissible in a STAT PDU.
Window
Sequence number of the first SD or SDP PDU not allowed by the
receiver.
Signaling Timers
203