15.1.2

List of Parameters

The following table lists the parameters.
Note: Do not change the following parameters from their default settings.
• Reserved parameters
• Parameters not given in this manual
• Parameters that are not valid for the Servomotor that you are using, as given in the parameter table
Parameter
No.
2
Pn000
2
Pn001
Setting
Name
Range
Basic Function Selec-
0000h to
tions 0
Rotation Direction Selection
Movement Direction Selection
Use CCW as the forward direction.
0
Use the direction in which the linear encoder counts up as the for-

n.
X
ward direction.
Use CW as the forward direction. (Reverse Rotation Mode)
1
Use the direction in which the linear encoder counts down as the
forward direction. (Reverse Movement Mode)

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)
Rotary/Linear Servomotor Startup Selection When Encoder Is Not Con-
nected
When an encoder is not connected, start as SERVOPACK for

n.X
0
Rotary Servomotor.
When an encoder is not connected, start as SERVOPACK for Lin-
1
ear Servomotor.
Application Function
0000h to
Selections 1
Motor Stopping Method for Servo OFF and Group 1 Alarms
0
Stop the motor by applying the dynamic brake.

n.
X
Stop the motor by the applying dynamic brake and then release
1
the dynamic brake.
2
Coast the motor to a stop without the dynamic brake.

n.
X
Reserved parameter (Do not change.)
Main Circuit Power Supply AC/DC Input Selection
Input AC power as the main circuit power supply using the L1, L2,
0
and L3 terminals (do not use shared converter).

n.
X
Input DC power as the main circuit power supply using the B1/
1
and
2 terminals or the B1 and
converter or the shared converter).

n.X
Reserved parameter (Do not change.)
Setting
Default
Unit
Setting
0000h
10B1h
0000h
1142h
2 terminals (use an external
15.1 List of Parameters
15.1.2 List of Parameters
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
page 5-16
Reference
page 5-15
After
All
Setup
restart
Reference
page 5-34
Reference
page 5-13
Continued on next page.
Refer-
ence
15
15-3