13.3.6

Smooth Stop Operation

To execute a Smooth Stop command, the deceleration rate that is set for the Servomotor is
used to stop the Servomotor.
1.
If the Smooth Stop bit is set to 1 while the Servomotor is moving, the Servomotor decel-
erates to a stop at the specified deceleration rate.
2.
After the motor stops, the target position is set to the current position, and the On Target
Position bit is set to 1.
3.
The smooth stop status can be cleared by clearing the Smooth Stop bit to 0. Execution
of the Smooth Stop command will continue even if the Smooth Stop bit is cleared to 0
during command execution (i.e., during deceleration).
Motor speed
Smooth Stop
Start Trajectory
Trajectory In
Progress
13.3.7

External Stop Operation

For the external stop operation, an emergency stop is performed in response to an external
signal.
If the external stop input signal (EXSTOP) is made active (turned OFF) while the Servomotor is
moving, a hard stop operation is performed. After the Servomotor has stopped, the servo is
turned OFF. If the brake function has been set, the brake will be turned ON, and then the servo
will be turned OFF.
To return to normal operation, make EXSTOP inactive (turn ON). If the Enable bit is already set
to 1, the servo is turned ON automatically.
Motor speed
1
EXSTOP
0
1
Enable
0
1
Holding Brake
0
1
Enable State-R
0
1
Start Trajectory
0
Trajectory In
1
Progress
0
A1
1
0
1
0
1
0
A1
13.3 Controlling Operation from the Host Controller