8.3.4

Vibration Detection Level Setting

You can set the vibration detection level (Pn312) to more accurately detect A.520 alarms
(Vibration Alarm) and A.911 warnings (Vibration Warning) when vibration is detected during
machine operation.
Set the initial vibration detection level to an appropriate value. Refer to the following section for
details.
6.11 Initializing the Vibration Detection Level on page 6-26
8.3.5
Setting the Position Deviation Overflow Alarm Level at
Servo ON
If the servo is turned ON when there is a large position deviation, the Servomotor will attempt to
return to the original position to bring the position deviation to 0, which may create a hazardous
situation. To prevent this, you can set a position deviation overflow alarm level at servo ON to
restrict operation.
The related parameters and alarms are given in the following tables.
Related Parameters
Position Deviation Overflow Alarm Level at Servo ON
Pn526
Setting Range
1 to 1,073,741,823
Position Deviation Overflow Warning Level at Servo ON
Pn528
Setting Range
10 to 100
• Rotary Servomotors
Speed Limit Level at Servo ON
Setting Range
Pn529
• Linear Servomotors
Speed Limit Level at Servo ON
Pn584
Setting Range
Related Alarms
Alarm Number
A.d01
A.d02
Refer to the following section for information on troubleshooting alarms.
14.2.3 Resetting Alarms on page 14-43
Setting Unit
1 reference unit
Setting Unit
1%
Setting Unit
0 to 10,000
1 min
Setting Unit
0 to 10,000
1 mm/s
Alarm Name
Position Deviation
This alarm occurs if the servo is turned ON after the position devia-
Overflow Alarm at
tion exceeded the setting of Pn526 (Excessive Position Deviation
Servo ON
Alarm Level at Servo ON) while the servo was OFF.
If position deviation remains in the deviation counter, the setting of
Position Deviation
Pn529 or Pn584 (Speed Limit Level at Servo ON) will limit the speed
Overflow Alarm for
when the servo is turned ON. This alarm occurs if a position refer-
Speed Limit at Servo
ence is input and the setting of Pn520 (Excessive Position Deviation
ON
Alarm Level) is exceeded.
8.3.4 Vibration Detection Level Setting
Default Setting
5,242,880
Default Setting
100
Default Setting
-1
10,000
Default Setting
10,000
Alarm Meaning
8.3 Precautions to Ensure Safe Tuning
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
8
8-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents