5.1.3

Parameter Setting Methods

You can use the SigmaWin+ or a Digital Operator to set parameters.
Use the following procedure to set the parameters.
Setting Parameters with the SigmaWin+
 Write data to flash memory only when the mechanical system is stopped.
If you write data to flash memory while the mechanical system is operating, processing that is
being executed will be interrupted and the mechanical system may stop.
1.
Click the
2.
Select Edit Parameters in the Menu Dialog Box.
The Parameter Editing Dialog Box will be displayed.
3.
Click the cell of the parameter to edit.
If the parameter to edit is not displayed in the Parameter Editing Dialog Box, click the
to display the parameter to edit.
4.
Change the setting of the parameter.
Information
5.
Press the Enter Key.
The background of the edited parameter cell will change to green.
Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
1. For a parameter for a numeric setting, input the numeric setting.
2. If the parameter requires selection of a function, select the function from the list of
selections.
5.1 Manipulating Parameters (Pn)

5.1.3 Parameter Setting Methods

DANGER
or
Button
5
5-5