Wiring Procedure For Main Circuit Connector - YASKAWA SGD7S Product Manual

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

4.3 Wiring the Power Supply to the SERVOPACK

4.3.2 Wiring Procedure for Main Circuit Connector

4.3.2

Wiring Procedure for Main Circuit Connector

• Required Items
Required Item
Spring Opener or Flat-
blade Screwdriver
1.
Remove the main circuit connector and motor connector from the SERVOPACK.
Locks
2.
Remove the sheath from the wire to connect.
3.
Open the wire insertion hole on the terminal connector with the tool. There are the fol-
lowing two ways to open the insertion hole. Use either method.
Using a Spring Opener
Open the insertion hole with the Spring Opener as
shown in the figure.
Spring Opener
Wire
4.
Insert the conductor into the wire insertion hole. Then, remove the Spring Opener or flat-
blade screwdriver.
5.
Make all other connections in the same way.
6.
When you have completed wiring, attach the connectors to the SERVOPACK.
4-14
• Spring Opener
SERVOPACK accessory
(You can also use model 1981045-1 from Tyco Electronics Japan G.K.)
• Flat-blade screwdriver
Commercially available screwdriver with tip width of 3.0 mm to 3.5 mm
1. Press in on
Main circuit
connector
Servomotor connector
8 mm to 9 mm
Remarks
Enlarged View
the lock.
2. Press in on the
Using a Flat-blade Screwdriver
Firmly insert a flat-blade screwdriver into the
screwdriver insertion hole to open the wire inser-
tion hole.
locks to remove
the connectors.