Manual operation and setup

12.8 Datum Setting with 3-D Touch Probe

12.8
Datum Setting with 3-D Touch Probe
Overview
The following soft-key functions are available for setting the datum
on an aligned workpiece:
Soft key
Function
Datum setting in any axis with
Setting a corner as datum
Setting a circle center as datum
Center line as datum
Datum setting in any axis
Select the probing function: Press the PROBING
POS soft key
Move the touch probe to a position near the touch
point
Use the soft keys to select the probe axis and
direction in which you want to set the datum, such
as Z in direction Z–
Start the probing procedure: Press the machine
START button
Datum: Enter the nominal coordinate and confirm
your entry with the SET DATUM soft key, See
"Writing measured values from the touch probe
cycles in a datum table", page 404
To terminate the probe function, press the END
soft key
HEIDENHAIN only gives warranty for the function of
the probing cycles if HEIDENHAIN touch probes are
used.