HEIDENHAIN TNC 320 User Manual page 472

Conversational programming
Hide thumbs Also See for TNC 320:
Table of Contents

Advertisement

15
MOD functions
15.8 Setting up data interfaces
Setting handshaking (flowControl)
By handshaking, two devices control data transfer between them.
A distinction is made between software handshaking and hardware
handshaking.
No data flow checking (NONE): Handshaking is not active
Hardware handshaking (RTS_CTS): Transmission stop is active
through RTS
Software handshaking (XON_XOFF): Transmission stop is active
through DC3 (XOFF)
File system for file operations (fileSystem)
In fileSystem you define the file system for the serial interface.
This machine parameter is not required if you don't need a special
file system.
EXT: Minimum file system for printers or non-HEIDENHAIN
transmission software. Corresponds to the EXT1 and EXT2
modes of earlier TNC controls.
FE1: Communication with the TNCserver PC software or an
external floppy disk unit.
Settings for data transfer with the TNCserver PC
software
Enter the following settings in the user parameters
(serialInterfaceRS232 / definition of data blocks for the serial
ports /
RS232):
Parameters
Data transfer rate in baud
Data transmission protocol
Data bits in each transferred
character
Type of parity checking
Number of stop bits
Specify type of handshake:
File system for file operations
472
Selection
Has to match the setting
in TNCserver
BLOCKWISE
7 bits
EVEN
1 stop bit
RTS_CTS
FE1
TNC 320 | User's Manual HEIDENHAIN Conversational Programming | 5/2013

Advertisement

Table of Contents
loading

Table of Contents