HEIDENHAIN TNC 320 User Manual page 255

Conversational programming
Hide thumbs Also See for TNC 320:
Table of Contents

Advertisement

Keyword
Function
HOUR
Number of hours from the real-time clock
MIN
Number of minutes from the real-time
clock
SEC
Number of seconds from the real-time
clock
DAY
Day from the real-time clock
MONTH
Month as a number from the real-time
clock
STR_MONTH
Month as a string abbreviation from the
real-time clock
YEAR2
Two-digit year from the real-time clock
YEAR4
Four-digit year from the real-time clock
In the part program, program FN 16: F-PRINT to activate the
output:
96 FN 16: F-PRINT TNC:\MASKE\MASKE1.A/ TNC:\PROT1.TXT
The TNC then creates the file PROT1.TXT:
MEASURING LOG OF IMPELLER CENTER OF GRAVITY
DATE: 27:11:2001
TIME: 8:56:34
NO. OF MEASURED VALUES : = 1
X1 = 149.360
Y1 = 25.509
Z1 = 37.000
If you output the same file more than once in the
program, the TNC appends all texts to the end of the
texts already output within the target file.
If you use FN 16 more than once in the program, the
TNC saves all texts in the file that you defined in the
FN 16 function. The file is not output until the TNC
reads the END PGM block, or you press the NC stop
button, or you close the file with M_CLOSE.
In the FN 16 block, program the format file and the
log file with their respective extensions.
If you enter only the file name for the path of the
log file, the TNC saves the log file in the directory
in which the NC program with the FN 16 function is
located.
You can define a standard path for outputting
protocol files via the user parameters
fn16DefaultPath and fn16DefaultPathSim (Program
Test).
TNC 320 | User's Manual HEIDENHAIN Conversational Programming | 5/2013