M800S/M80 Series Connection and Setup Manual
7 Connection of Control Unit
7.3 Connecting with Emergency Stop Signal
Connect the emergency stop switch to EMG connector of the control unit.
Control unit
LG
Emergency stop input circuit
<Related items>
Cable drawing: "Cable: J120 Cable"
Connector pin assignment: "General Specifications: Control Unit" (EMG connector)
IB-1501269-F
Control unit
EMG
+24V
R
EMGIN
FG
J120
Emergency
stop switch
186
Emergency
stop switch