Cnv2E-Hp Cable - Mitsubishi M80 series Connection And Set Up Manual

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
15 Cable

15.3.6 CNV2E-HP Cable

Max. cable length: 30m
Application: MDS-B-HR unit cable
Drive unit side connector
Receptacle: 36210-0100PL
Shell kit: 36310-3200-008
Connector set: 54599-1019
Case
grounding
(3M)
(MOLEX)
P5(+5V)
1
2
LG
10
RQ
3
RQ*
4
5
6
SD
7
8
SD*
PE
<Cable connection diagram>
MDS-B-HR unit side connector
(Hirose Electric)
Plug: RM15WTPZ-8S(71)
Clamp: JR13WCCA-10(72)
2
0.5mm
5
P5(+5V)
7
LG
2
0.5mm
6
P5(+5V)
8
LG
2
0.2mm
1
RQ
2
RQ*
2
0.2mm
3
SD
4
SD*
Case
PE
grounding
303