Mitsubishi M80 series Connection And Set Up Manual page 179

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
Signal explanation
HOST
terminal No.
1
FG
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6
0V
7
RS(RTS)
8
CS(CTS)
9
SW2_C11
10
SW2_C12
11
SW1_NC11
12
SW1_NC12
13
24VDC(-)
14
SD(TXD)
15
RD(RXD)
16
HA
17
HB
18
SW6_NO1
19
SW6_C1
20
0V
21
SW2_C21
22
SW2_C22
23
SW1_NC21
24
SW1_NC22
25
24VDC(+)
(Note)
The input/output goes to/from the handy terminal.
IB-1501269-F
HOST connector
Input/
signal name
Output
-
-
-
-
-
-
O
I
-
-
-
-
I
O
I
O
O
-
-
-
-
-
-
-
I
Function/ Name
Frame ground
Reserved
Reserved
Reserved
Reserved
Ground
RS-232C communication signal (Request To Send)
RS-232C communication signal (Clear To Send)
Enable switch contact 1 terminal 1
Enable switch contact 1 terminal 2
Emergency stop switch contact 1 terminal 1
Emergency stop switch contact 1 terminal 2
24VDC ground
RS-232C communication signal (Send Data)
RS-232C communication signal (Receive Data)
Manual pulse generator A phase signal
Manual pulse generator B phase signal
Switchover switch terminal 1
Switchover switch terminal 2
Ground
Enable switch contact 2 terminal 1
Enable switch contact 2 terminal 2
Emergency stop switch contact 2 terminal 1
Emergency stop switch contact 2 terminal 2
24VDC input